Your location:Home > Product
Product
| HV self-regulating & middle temperature electric heating cable |
| SPECIFICATION: |
| Self-regulating and save energy |
| Voltage 220V/110V |
| Max Using Length 120 m |
| Max Heat tracing Temperature 110℃ |
| the most Suitable Temperature for heat tracing 80℃ |
| Outline Size 4.6×11.7 mm |
| Local Cutting at random |
| 28 W/m、41W/m(10℃) |
| Min. Bending Radius 30mm |
| Fitting for Explosion-proof Area 1、2 |
| Temperature group T4 | |
|
| Heat Output for Cable W/m |
| A 14AWG Copper Bus Wires |
| B Semiconductor Heating Core |
| C Insaluting Jacket |
|
D Tinned Copper Braid |
| E Overjacket(optional) |
|
|
Type |
Output Power |
|
45HV-2SJ |
45.0-0.37Tp |
|
30HV-2SJ |
30.3-0.24Tp | |
| Record:Tp is the pipe temperature | |
 |
| Circuit breaker selection(Unit: Meter) |
|
Cable Type |
Openning Temp.10℃ |
Openning Temp.-10℃ |
Openning Temp.-30℃ |
|
15A |
20A |
30A |
40A |
15A |
20A |
30A |
40A |
15A |
20A |
30A |
40A |
50A |
|
30HV-2SJ |
43 |
57 |
86 |
114 |
39 |
52 |
78 |
104 |
36 |
49 |
72 |
98 |
120 |
|
45HV-2SJ |
38 |
51 |
76 |
100 |
36 |
48 |
72 |
96 |
33 |
44 |
66 |
88 |
100 |
| Suggestion: PLS using the thermal magnetic circuit breaker . For it can “nuisance trip” at low temperature. | |
| Type Number Nomenclature: |
 |
|
|
 |